- A mid-infrared dual-comb spectrometer in step-sweep mode for high-resolution molecular spectroscopy To meet the challenges of high-resolution molecular spectroscopy, increasingly sophisticated spectroscopic techniques were developed. For a long time FTIR and laser-based spectroscopies were used for these studies. The recent development of dual-comb spectroscopy at high-resolution makes this technique a powerful tool for gas phase studies. We report on the use and characterization of the IRis-F1, a tabletop mid-infrared dual-comb spectrometer, in the newly developed step-sweep mode. The resolution of the wavenumber axis is increased by step-wise tuning (interleaving) and accurate measurement of the laser center wavelength and repetition frequency. Doppler limited measurements of N2O and CH4 reveal a wavenumber accuracy of 1E-4 cm-1 on the covered range of > 50 cm-1. Measured half-widths of absorption lines show no systematic broadening, indicating a negligible instrument response function. Finally, measurements of nitrogen pressure broadening coefficients in the v4 band of methane show that quantum cascade laser dual-comb spectroscopy in step-sweep mode is well adapted for measurements of precision spectroscopic data, in particular line shape parameters. 9 authors · Mar 5, 2024
- Benchmarking the CoW with the TopCoW Challenge: Topology-Aware Anatomical Segmentation of the Circle of Willis for CTA and MRA The Circle of Willis (CoW) is an important network of arteries connecting major circulations of the brain. Its vascular architecture is believed to affect the risk, severity, and clinical outcome of serious neurovascular diseases. However, characterizing the highly variable CoW anatomy is still a manual and time-consuming expert task. The CoW is usually imaged by two non-invasive angiographic imaging modalities, magnetic resonance angiography (MRA) and computed tomography angiography (CTA), but there exist limited datasets with annotations on CoW anatomy, especially for CTA. Therefore, we organized the TopCoW challenge with the release of an annotated CoW dataset. The TopCoW dataset is the first public dataset with voxel-level annotations for 13 CoW vessel components, enabled by virtual reality technology. It is also the first large dataset using 200 pairs of MRA and CTA from the same patients. As part of the benchmark, we invited submissions worldwide and attracted over 250 registered participants from six continents. The submissions were evaluated on both internal and external test datasets of 226 scans from over five centers. The top performing teams achieved over 90% Dice scores at segmenting the CoW components, over 80% F1 scores at detecting key CoW components, and over 70% balanced accuracy at classifying CoW variants for nearly all test sets. The best algorithms also showed clinical potential in classifying fetal-type posterior cerebral artery and locating aneurysms with CoW anatomy. TopCoW demonstrated the utility and versatility of CoW segmentation algorithms for a wide range of downstream clinical applications with explainability. The annotated datasets and best performing algorithms have been released as public Zenodo records to foster further methodological development and clinical tool building. 113 authors · Dec 29, 2023